Model NO.: HGM750/6 Installation Method: Fixed Cooling Method: Water Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Voltage Range: 3kv-13.8kv Application Area: Power Plant , High Voltage, Black Start Alternator Standard: BS5000, VDE0530, NEMA Mg1-32, IEC34, IEC60034, As1 Controller: Deif, Deep Sea, Comap, etc Alternator: Marathon, Engga, Leroy Somer, Mecc Alte Specification: ISO8528 HS Code: 85021300 Type: Self-Starting
diesel generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Low Noise Frequency&Speed: 50Hz&1500rpm Warranty: 1 Year or 1000hours Engine Standard: ISO9001, GB/T2820-97, ISO8528 Engine Model: Googol High Voltage
Diesel Engine Load Mode: Fixed Output or Auto Load Sharing Trademark: Honny Origin: Guangdong, China 540kW 650kVA Diesel Fuel 60Hz Certificate Open Generator
Generator Set | Genset Model | HCM700/6 | HGM750/6 |
Rating Power (KW/KVA) | 510/635 | 540/675 |
Standby Power(KW/KVA) | 560/700 | 600/750 |
Rating Ammeter(A) | 940 | 1000A |
diesel engine | General data | Engine model | Cummins KTAA19-G6A | Googol PTAA1120-G4 |
Prime Power(KW/HP) | 549/746 | 578/722 |
Standby Power(KW/HP) | 610/829 | 636/794 |
number of Cylinder & Configuration | 6 cylinders in line | V10 type |
Bore X Stroke (mm) | 159X159 | 128*142 |
Displacement(l) | 19 | 17 |
Compression Ratio | 13.9:1 | 14.6:1 |
Governor type | Electronic governor | Electronic governor |
Rated RPM | 1800 | 1800 |
Exhaust system | Exhaust gas flow(m³/min) | 131 | 68 |
Max. Exhaust Gas Temperature(ºC) | 515 | 500 |
Max. Exhaust back Pressure(KPA) | 10 | 5 |
Air intake system | Aspiration Type | Turbo & Air-Air cooled | Turbo & Air-Air cooled |
Max. intake depression(mbar) | 6 | 6 |
Combustion air Volume(m³/min) | 40.3 | 46.69 |
Fuel system | Rating Fuel Consumption(l/h) | 143 | 128.9 |
75% full Fuel Consumption(l/h) | 145 | 110 |
Lubrication system | Total oil capacity(l) | 72 | 40 |
Max permissible oil temp(ºC) | 121 | 110 |
Oil pressure at rated rpm(KPA) | 276-414 | 280-420 |
Cooling system | Total Coolant capacity(l) | 96 | 21 |
Max. temperature of coolant(ºC) | 100 | 90 |
Fan cooling air flow(m³/min) | 735 | 688 |
Alternator | Alternator model | GP700-4P Googol | GP700-4P Googol |
Rating Voltage(V) | 440/220 | 440/220 |
Rating Capacity(KW/KVA) | 560/700 | 560/700 |
Eff.% | 94.25% | 94.25% |
Power Factor | 0.8 | 0.8 |
Exciting type | Brushless self-exciter AVR | Brushless self-exciter AVR |
Voltage regulation | ±1% | ±1% |
No. of Phase | 3 phase 4 wire | 3 phase 4 wire |
Enclosure Class | IP21 | IP21 |
Class of Insulation | H | H |
Battery | Rating Capacity(AH) | 2X200AH 12V | 2X200AH 12V |
Dimension | Generator set dimension (LXWXH) | 3750x1500x1900 | 5200X1700X2400 |
Weight | Generator set Net Weight (kg) | 5200 | 4000 |
Googol High voltage series generator sets, power range is from 800kVA to 5000kVA, standard voltage or high voltage generating system.
Enigne Brand: Perkins engine, Cummins engine, Googol engine, CSR engine
Alternator voltage: 3300V, 6300V, 10500V, 3600V, 6600V, 11000V, 13800V
Frequency: 50Hz or 60Hz
Speed: 1500rpm, 1800rpm, 1200rpm, 1000rpm according to the engine brand
Performance Feature:
Engine and alternator shall be mounted on a same frame steel skid.
Small size, low weight, easy to operating, installation and maintenance.
Good Quality diesel engine.
World famous brand
AC Alternator: Stamford, Marathon, Leroy Somer, MVC, Engga.
Advanced and reliable control module: Key start, Auto start, Remote control by PC with RS232/485
Full range protect function and alarm shutdown feature.
Standard Control System: Deepsea 7320 AMF
Mains 3 phases VPh-N L1-N L2-N L3-N
Mains 3 phases VPh-pH L1-L2 L2-L3 L3-L1
Mains frequency Hz (L1)
Gen 3 phases VPh-N L1-N L2-N L3-N
Gen 3 phases VPh-pH L1-L2 L2-L3 L3-L1
Gen 3 phases current I1 I2 I3
Gen frequency Hz (L1)
Gen total apparent power ∑ A
Gen total active power ∑ P
Gen power factor PF (AV)
Genset speed RPM (signal from generator voltage frequency)
Engine oil pressure Bar (signal from engine P-sensor)
Engine coolant temperature (signal from engine T-sensor)
Battery voltage VDC
Genset Running hour Hour
Standard Accessory:
Common steel base frame, anti-vibrator, Exhaust silencer, Flexible pipe, Battery connecting wires, Operation manual and document.
Optional Accessory:
Circuit breaker, Starting Battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS and paralleling system, Soundproof Canopy and Moving Trailer.
Usage: Power plant, black start, emergency standby, large factory, data center, mining plant
Let's achieve our goal together, Using power to kindle the dream of human.
Contact us if you need more details on
High Voltage Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about
60Hz Generator、
540kw Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : High Voltage Generators