Find High Voltage Generator, 60Hz Generator, 540kw Generator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.
New Products
Payment Type: | L/C, T/T |
---|---|
Min. Order: | 1 |
Model No.: HGM3125HV
Engine Model | QTA5400G3-HV | |
Speed | rpm | 1500 |
Frequency | Hz | 50 |
Rating Output | ||
Standby Output ( LTP) | kW | 2563 |
Prime Output (PRP) | kW | 2333 |
Engine Continuous Power (COP) | kW | 1979 |
Fan Quantity | 4 | |
Fan Reduction | kW | 22.0 |
Single Fan Reduction | kW | 20.0 |
All Fans Reduction | kW | 80.0 |
Engine Net Standby Output ( LTP) | kW | 2563 |
Engine Net Prime Output (PRP) | kW | 2333 |
Engine Net Continuous Output (COP) | kW | 1979 |
BMEP for Standby Output | bar | 23.16 |
BMEP for Prime Output | bar | 21.09 |
BMEP for Continuous Output | bar | 17.89 |
Typical Generation Standby Output | kVA | 3075 |
Typical Generation Standby Output | kW | 2460 |
Typical Generation Prime Output | kVA | 2800 |
Typical Generation Prime Output | kW | 2240 |
Typical Generation Continuous Output | kVA | 2375 |
Typical Generation Continuous Output | kW | 1900 |
Typical Alternator Efficiency | ≥ | 96.0% |
Voltage of Genset | V | 11000 |
MECC alte Generator's Model | * | |
MARATHON Generator's Model | MXH-2000-4 | |
Coupler Model | ZL9-01 | |
Power Factor | 0.8 | |
Speed droop (static) elect. Gov. | 0-5% | |
Governing standards to ISO 8528 Parts 1 and 5 | G3 | |
Max. step load acceptance, 1st step ( % Prime Output ) | 43% | |
Basic Performance Datasheet | ||
Aspiration Type | Turbocharger, air-water aftercooler | |
Injection Type | Direct Injection | |
Configuration | Vee | |
No. of Cylinders | 20 | |
Displacement | l | 88.5 |
Bore | mm | 170 |
Stroke | mm | 195 |
Compression Ratio | 13.5:1 | |
Piston Speed | m/s | 9.75 |
Rotation Direction (from flywheel) | Counter Clockwise | |
Number of Flywheel Teeth | 218 | |
Flywheel House Size | SAE00-21 | |
Lubrication System | ||
Lube Oil Specification | API-CF4 | |
Oil Capacity | l | 300 |
Max. Permissible Oil Temperature | °C | 110 |
Oil Pressure Warning | kPa | 300 |
Oil Pressure Shutdown | kPa | 200 |
Cooling System | ||
Coolant Capacity for Engine | l | 200 |
Max. Permissible Temperature | °C | 90 |
Max. Coolant Warning Temperature | °C | 95 |
Max. Coolant Shutdown Temperature | °C | 98 |
Thermostat OPEN Temperature | °C | 71 |
Radiator Cooling Flow | m³/min | 3800 |
Flow of Cylinder liner Coolant pump | m³/h | 80 |
Flow of aftercooler Coolant pump | m³/h | 75 |
Heat dissipation (engine radiator) | kW | 751 |
Heat dissipation (CAC) | kW | 369 |
Heat dissipation (convection) | kW | 128 |
Mode of Radiator(cooper core , 40 C environment's temp ) | 6310262 | |
Fuel System | ||
Governor Type | Electrical | |
Engine Output at genset prime output | kW | 2333 |
Fuel Consumption at 25% of genset prime output | l/h | 170.01 |
Fuel Consumption at 50% of genset prime output | l/h | 293.12 |
Fuel Consumption at 75% of genset prime output | l/h | 403.71 |
Fuel Consumption at 100% ofgenset prime output | l/h | 532.95 |
Lowest Fuel Consumption Ratio | g/kW.hr | 190.72 |
Intake & Exhaust System ( On Standby Output ) | ||
Combustion Air Consumption | m³/min | 258.85 |
Max. Intake Restriction | KPa | 2 |
Exhaust Temperature (Before Turbo) | °C | 630 |
Exhaust Temperature (After Turbo) | °C | 510 |
Max. Exhaust Back Pressure | KPa | 2 |
Exhaust Gas Flow | m³/min | 655.03 |
Exhaust Flange Diameter | mm | 2*250 |
Electrical System | ||
Charging Alternator Voltage | V | 28 |
Charging Alternator Capacity | A | 55 |
Starting Voltage | V | 24 |
Starting Motor Capacity | kW | 2*13 |
Minimum Battery Capacity | Ah | 4*200 |
Quantity of generator set's Bearing (( For 400-660VAC generator ) | 2 | |
Quantity of generator set's Bearing (( For Above 3300VAC generator ) | 2 | |
Engine Dimension | ||
Length | mm | 4110 |
Width | mm | 1459 |
Height | mm | 1820 |
Engine Dry Weight w/o Cooling System | kg | 7750 |
Product Categories : High Voltage Generators