Find Generator Set, Diesel Generating Set, Diesel Generation Set on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Googol Generators > 50Hz AC Three Phase Synchronous Brushless Diesel Generator 400kw 500kVA

50Hz AC Three Phase Synchronous Brushless Diesel Generator 400kw 500kVA

Payment Type: L/C, T/T
Min. Order: 1

Basic Info

Model No.:  HGM550

Product Description

Model NO.: HGM550 Installation Method: Fixed Cooling Method: Water Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Alternator Model: Meccalte Eco40-3s/4 Voltages: Low Voltage 380V , 400V ,Adjustable Warranty: 1 Year or 1000hours Canopy Types: Silent ,Container,Trailer ,etc Weight: 3410kg Specification: ISO8528 HS Code: 8502131000 Type: Self-Starting diesel generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Low Noise Engine Model: Googol Ptaa890 Controller Model: Deep Sea, Comp, Datakom , etc Certificates: CE,ISO.BV,GOST,Tus,SGS Prime Power: 400kw/500kVA Option: ATS,Circuit Breaker,Panels Trademark: HONNY Origin: Guangdong, China 50Hz AC Three Phase Synchronous Brushless Diesel Generator 400kW 500kVA

Features:
Honny Power provides one-source responsibility for the generating system and accessories.
The Generator Set and its components are prototype-tested, factory-built, and production-tested.
The generator set accepts rated load in one step.
A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available.

Alternator features:
The pilot-excited, permanent-magnet (PM) alternator provides superior short-circuit capability.
The brushless, rotating-field alternator has broad range reconnectability.
NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting.
Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.
Sustained short-circuit current enabling down stream circuit breakers to trip without collapsing the alternator field.
Self-ventilated and drip-proof construction.
Superior voltage waveform from a two-thirds pitch stator and skewed rotor.
Digital solid-state, volts-per-hertz voltage regulator with around 0.25% no-load to full-load regulation.
Brushless alternator with brushless pilot exciter for excellent load response.

Other Features:
Controllers are available for all applications.
The low coolant level shutdown prevents overheating (standard on radiator models only).
Integral vibration isolation eliminates the need for under-unit vibration spring isolators.
An electronic, isochronous governor delivers precise frequency regulation.
Multiple circuit breaker configurations.
Standard Supply:

Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.

Optional Accessories:

Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & Paralleling System, and Moving Trailer.

Packaging& Shipping
1, Plastic film package, depends on Client's requirement
2, 35days after First Payment, Accept FOB, CIF, EXW, etc
Generator Model HGM550
Genset Prime Power 400kW/500kVA

Engine Ratings:
Engine Speed (RPM) 1500
Generator set Frequency (Hz) 50
Engine Standby Power (LTP) (kW) 491 
Engine Prime Power (PRP) (kW) 448 
Engine Continuous Power (COP) (kW) 341 
Single Fan Power (kW) 20
Single Fan Consumption (kW) 20
Quantity of Fan (Sets) 1
All Fan Consumption (kW) 20
Engine Net Standby Output  (LTP) (kW) 471 
Engine Net Prime Output  (PRP) (kW) 428 
Engine Net Continuous Output  (COP) (kW) 321 
BMEP for Standby Output (bar) 26.84 
BMEP for Prime Output  (bar) 24.48 
BMEP for Continuous Output  (bar) 18.68 
Typical Generation Standby Output  (kVA) 550
Typical Generation Standby Output  (kW) 440
Typical Generation Prime Output  (kVA) 500
Typical Generation Prime Output  (kW) 400
Typical Generation Continuous Output  (kVA) 375
Typical Generation Continuous Output  (kW) 300
Typical  Alternator Efficiency  93.5%
Power Factor
0.8
Speed droop (static) elect. Gov.
0-5%
Governing standards to ISO 8528 Parts 1 and 5
G3
Max. step load acceptance, 1st step(% Prime Output)
53%

Basic Performance Datasheet
Aspiration Type
Turbocharger, air-air after-cooler
Injection Type
Direct Injection
Configuration
In Line
No. of Cylinders
8
Displacement (liters) 14.6
Bore (mm) 128
Stroke (mm) 142
Compression Ratio
14.6:1
Piston Speed (m/s) 7.10
Rotation Direction (from flywheel)
                     Counter Clockwise
Number of Flywheel Teeth
160
Flywheel House Size
SAE1-14

Lubrication System
Lube Oil Specification
AFI-CF4
Oil Capacity ( Liters) 32
Max. Permissible Oil Temperature  (°C) 110
Low Oil Pressure Warning  (kPa) 200
Low Oil Pressure Shutdown  (kPa) 160
Oil consumption (as % of fuel consumption)
≤0.5

Cooling System
Coolant Capacity for Engine ( Liters) 20
Max. Permissible Temperature  (°C) 90
Max. Coolant Warning Temperature  (°C) 95
Max. Coolant Shutdown Temperature  (°C) 105
Thermostat OPEN Temperature  (°C) 71
Radiator Cooling Flow (m³/min) 574
Flow of Coolant pump (m³/h) 25.98 
Heat dissipation (engine radiator) (kW) 237 
Heat dissipation (convection) (kW) 36 
Radiator Model
PSCN3000

Fuel System
Governor Type
Electrical Control
Engine Output at generator set prime output (kW) 448 
Fuel Consumption at 25% of generator set prime output (l/h) 33.93 
Fuel Consumption at 50% of generator set prime output (l/h) 59.04 
Fuel Consumption at 75% of generator set prime output (l/h) 84.91 
Fuel Consumption at 100% of generator set prime output (l/h) 113.58 
Lowest Fuel Consumption Ratio g/kW.hr 211.11 

Intake & Exhaust System(On Standby Output)
Combustion Air Consumption (m³/min) 36.79 
Max. Intake Restriction (Kpa) 5
Max. Exhaust Temperature(Before Turbo) (°C) 675
Max. Exhaust Temperature(After Turbo) (°C) 430
Max. Exhaust Back Pressure (Kpa) 5
Exhaust Gas Flow (m³/min) 44.97 
Exhaust Flange Diameter (mm) 2*100

Electrical System
Charging Alternator Voltage (V) 28
Charging Alternator Capacity (A) 55
Starting Voltage (V) 24
Starting Motor Capacity (kW) 1*6.6
Minimum Battery Capacity (Ah) 2*200
Minimum Temperature for Unaided Cold Start (C) 10

Engine Dimension
Length (mm) 1484
Width (mm) 1389
Height (mm) 1162
Engine Dry Weight w/o Cooling System (kg) 1125
Note:
1,All engine parameters are in accordance with ISO3046, ISO8528
2,All engine parameters are based on 25°C / 100kPa environment condition
3,No power decrease with below 40ºC environment temperature and 1500 meter altitude
4,More than 40ºCand 1500m above sea level , decrease 2% per 10ºC , and 4% per 300m
5,At calorific value 42700 kJ/kg + 5%, density 0,835 kg/dm3 , temperature 280 K
6,Above data is only the testing data in our laboratory, it can't used to be the data on all contract
Alternator Alternator model MGA355-400-4SF
Rating Voltage(V) 400/230V,380/220V adjustable
Rating Capacity(KW/KVA) 400/500
Eff.% 95.1%
Power Factor 0.8
Exciting type Brushless self-exciter AVR
Voltage regulation ±1%
No. of  Phase 3 phase 4 wire
Enclosure Class IP21
Class of Insulation H
 
Standard Accessory  Battery 2X200AH 12V
Battery Wires 1 set
Flexible Pipe 2*6 inch
Industry Silencer 2*6 inch
Optional Accessory VCB Breaker Panel 800A
Fuel Tank 500 Liter
Fuel-water Separator 
Heater Coolant & Oil Heater
50Hz AC Three Phase Synchronous Brushless Diesel Generator 400kw 500kVA
50Hz AC Three Phase Synchronous Brushless Diesel Generator 400kw 500kVA

Contact us if you need more details on AC Three Phase Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Synchronous Diesel Generator、Brushless Diesel Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Googol Generators